English Deutsch Français 简体中文 繁體中文
Book123, Download eBooks for Free - Anytime! Submit your article

Categories

Share With Friends



Like Book123?! Give us +1

Archive by Date

Search Tag

Newest

Useful Links


Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner

Posted on 2010-05-11




Name:Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner
File size:7.8 Mb
   Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner

Free Download Now     Free register and download UseNet downloader, then you can FREE Download from UseNet.

    Download without Limit " Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner " from UseNet for FREE!


Johnson Controls Unitary Products 542245-UTD-B-1109 TABULAR DATA SHEET Outdoor Split System Air Conditioner 2 Thru 5 Tons MODELS: TCGF24* THRU 60 14.5 SEER - R-410A, 1 PHASE All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. Physical and Electrical Data MODEL TCGF24S41S3 TCGF30S41S3 TCGF36S41S3 TCGF42S41S3 TCGF48S41S3 TCGF60S41S3 Unit Supply Voltage 208-230V, 1?? 60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 16.8 18.4 19.1 23.9 27.9 35.9 Max. Overcurrent Device Amps 2 25 30 30 40 45 60 Min. Overcurrent Device Amps 3 20 20 20 25 30 40 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor Amps Rated Load 12.8 14.1 14.1 17.9 21.1 27.5 Locked Rotor 58 73 77 112 115 135& 8230;.

Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/8 1 1/8 Unit Charge (Lbs. - Oz.) 4 3 - 2 3 - 7 3 - 10 4 - 4 4 - 9 5 - 9 Charge Per Foot, Oz. 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 128 130 145 172 180 199 1. Rated in accordance with ARI Standard 110, utilization range & 8220;A& 8221;. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. The Unit Charge is correct for the outdoor unit, smallest matched evaporator coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value & 8230; Subject to change without notice. Published in U.S.A. 542245-UTD-B-1109 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 542245-UTD-A-1009 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing. 2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table. 3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table. 4. For TXV match charge weight needs to be weighed in for specific coil match and lineset length. 5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. System Charge for Various Matched Systems Outdoor Unit TCGF24S41S3 TCGF30S41S3 TCGF36S41S3 TCGF42S41S3 TCGF48S41S3 TCGF60S41S3 Required Orifice or TXV 1 1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

Buy It at Lowest Price on Amazon

TABULAR DATA SHEET Outdoor Split System Air Conditioner.Pdf

Rating:

2.5 out of 5 by

 
Download Links
  ServerStatus
  Direct Download Link 1Alive
  Direct Download Link 2Alive
  Download Link (Download)Alive


Buy This Book at Best Price >>

Like this article?! Give us +1:

Related Articles


Magazine Key to Reducing Risk from Unauthorized Applications, Free McAfee Data Sheet

Magazine Key to Reducing Risk from Unauthorized Applications, Free McAfee Data Sheet

Free PDF: Windows Mobile Data Sheet

Free PDF: Windows Mobile Data Sheet

Windows Mobile Data Sheet_Final A.indd. Windows Mobile 6 Delivering Great Performance and Value for IT Professionals With a … .. Professionals With a host of new features and enhanceme/s, Windows Mobile® 6 helps your organization e ...

Free PDF: CISCO AIRONET 802.11A/B/G WIRELESS CARDBUS ADAPTER DATA SHEET

Free PDF: CISCO AIRONET 802.11A/B/G WIRELESS CARDBUS ADAPTER DATA SHEET

The adapter supports WPA2—the Wi-Fi Alliance certification for interoperable, standards-based wireless LAN security. The Cisco Aironet 802.11a/b/g Wireless CardBus Adapter supports … Cisco Systems, Inc. All rights reserved. Important ...

Free PDF: Air Conditioner Operating Tips

Free PDF: Air Conditioner Operating Tips

Provide Good Air Flow to Outdoor Cooling Equipment The outdoor unit of the air conditioner contains a condensing coil, a type of heat exchanger which depends on large quantities of air … Helping You Live Energy Efficiently! Energy Bri ...

Free PDF: Replacing Air Conditioner cluch on “Fixed Displacement” C171 Mopar Compressor

Free PDF: Replacing Air Conditioner cluch on “Fixed Displacement” C171 Mopar Compressor

at the clutch coil. • If the current is more than 4 amps, the coil is shorted and should be replaced. C171 Mopar. A/C Compressor … When I looked at the damage later, I found that the front plate (the metal plate on the front of t ...

Free PDF: DELUXE HIGH WALL MINI SPLIT INSTALLATION INSTRUCTIONS

Free PDF: DELUXE HIGH WALL MINI SPLIT INSTALLATION INSTRUCTIONS

DELUXE HIGH WALL MINI SPLIT INSTALLATION INSTRUCTIONS IMPORTANT! Please read this instruction … the system is most likely undercharged, and charge should be added. The air conditioner is … This air conditioning system meets stri ...

Share this page with your friends now!
Text link
Forum (BBCode)
Website (HTML)
Tags:
Conditioner   SHEET   DATA   Free  
 

DISCLAIMER:

This site does not store Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner on its server. We only index and link to Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner provided by other sites. Please contact the content providers to delete Free PDF: TABULAR DATA SHEET Outdoor Split System Air Conditioner if any and email us, we'll remove relevant links or contents immediately.

Comments (0) All

Verify: Verify

    Sign In   Not yet a member?

Sign In | Not yet a member?